Sub PCB Communication Error — Main MICOM to Sub MICOM

Moderate

Address soon - your appliance may not work properly

How to Fix

  1. 1

    Check all connectors between main PCB and sub PCB for loose or disconnected wiring. Reconnect as needed.

  2. 2

    Measure voltage at Sub CON1 8th Pin to 33rd Pin. Expected: not 0 or 5 V (oscillating). If static 0 or 5, check Sub PCB connection — replace Sub PCB if connection is good.

  3. 3

    Measure voltage at Sub CON1 10th Pin to 33rd Pin. Expected: not 0 or 5 V. If static, check Sub PCB connection — replace Sub PCB if connection is good.

  4. 4

    Measure voltage at Main CON3 1st Pin to 15th Pin. Expected: not 0 or 5 V. If static, check Display PCB connection — replace Display PCB if connection is good.

  5. 5

    Measure voltage at Main CON3 3rd Pin to 15th Pin. Expected: not 0 or 5 V. If static, check Display PCB connection — replace Display PCB if connection is good.

  6. 6

    If all checks pass, explain normal operation to customer.